Abstract
This document specifies the method for the calibration of hand torque tools and describes the method of calculation of measurement uncertainties for the calibration.
It also specifies the minimum requirements for a certificate of calibration to this standard for hand torque tools.
The Annex C of this document specifies the minimum requirements for the calibration of the torque measurement device where the relative measurement uncertainty interval, W´md, is not already provided by a traceable calibration certificate.
This document applies to hand torque tools which are classified as indicating torque tools (Type I) and setting torque tools (Type II).
NOTE Hand torque tools covered by this document are those identified in ISO 1703:2018 by reference numbers 7 1 00 01 0 to 7 1 00 14 0 inclusive. Torque limiting hand torque tools do not yet have reference numbers and will not do so until the next revision of ISO 1703
General information
-
Status: Under developmentStage: CD approved for registration as DIS [30.99]
-
Edition: 2
-
Technical Committee :ISO/TC 29/SC 10
- RSS updates
Life cycle
-
Previously
PublishedISO 6789-2:2017
-
Now